部位
|
组合1
|
组合2
|
|
上节桩型
|
PRHC
|
PHC
|
|
中段桩型
|
PRHC+PHC 或
PHC+PHC 或
PHC+PHDC
|
PHC+PHC或
PHC+PHDC或PHDC+PHDC
|
|
下节桩型
|
PHDC
|
PHDC
|


|
土 层
|
顶面高/m
|
层厚
/m
|
实测标贯/N
|
预制桩/kPa
|
|
|
qsik
|
qpk
|
||||
|
①1a杂填土
|
-1.04
|
5.00
|
|||
|
①2黏土
|
-2.19
|
1.15
|
10.5
|
50
|
|
|
②2淤泥质粘土
|
-9.04
|
6.85
|
20
|
||
|
②2b粉土夹粉砂
|
-13.04
|
4.00
|
7.7
|
36
|
|
|
②3淤泥质粉质粘土
|
-15.04
|
2.00
|
4.0
|
22
|
|
|
④1淤泥质粉质粘土
|
-19.04
|
4.00
|
3.5
|
22
|
|
|
④2粘土
|
-27.04
|
8.00
|
6.7
|
44
|
|
|
⑤1粉质粘土
|
-30.34
|
3.30
|
41.0
|
72
|
2200
|
|
⑤5圆砾
|
-32.44
|
2.10
|
58.0
|
110
|
7500
|
|
⑥1粉质粘土
|
-36.04
|
3.60
|
20.7
|
65
|
|
|
⑥2粉质粘土
|
-39.24
|
3.20
|
13.0
|
50
|
|
|
⑥5圆砾
|
-42.54
|
3.30
|
45.4
|
110
|
|
|
⑧3砾砂
|
-46.84
|
4.30
|
55.9
|
110
|
|
|
⑨1粉质粘土
|
-48.94
|
2.10
|
31.3
|
75
|
3600
|
|
⑨1a碎石
|
-52.94
|
4.00
|
54.5
|
150
|
9000
|
|
⑨1粉质粘土
|
-57.19
|
4.25
|
31.3
|
75
|
3600
|
|
⑨2圆砾
|
-68.80
|
11.61
|
55.5
|
110
|
7500
|

|
加载值
/kN
|
试验桩1
|
试验桩2
|
||
|
SS
/mm
|
SX
/mm
|
SS
/mm
|
SX
/mm
|
|
|
2×1200
|
0.05
|
-0.09
|
0.04
|
-0.16
|
|
2×1800
|
0.08
|
-0.16
|
0.06
|
-0.31
|
|
2×2400
|
0.16
|
-0.29
|
0.11
|
-0.58
|
|
2×3000
|
0.25
|
-0.47
|
0.18
|
-0.97
|
|
2×3600
|
0.36
|
-0.68
|
0.27
|
-1.48
|
|
2×4200
|
0.49
|
-1.02
|
0.37
|
-2.16
|
|
2×4800
|
0.65
|
-1.54
|
0.48
|
-2.86
|
|
2×5400
|
0.82
|
-2.36
|
0.60
|
-3.62
|
|
2×6000
|
1.03
|
-3.32
|
0.73
|
-4.40
|
|
2×6600
|
1.25
|
-4.35
|
0.87
|
-5.21
|
|
2×7200
|
1.48
|
-5.67
|
1.02
|
-6.05
|
|
2×7800
|
1.72
|
-7.23
|
1.19
|
-6.94
|
|
2×6600
|
1.64
|
-6.86
|
1.14
|
-6.60
|
|
2×5400
|
1.50
|
-6.37
|
1.06
|
-6.12
|
|
2×4200
|
1.29
|
-5.62
|
0.94
|
-5.49
|
|
2×3000
|
1.01
|
-4.69
|
0.79
|
-4.74
|
|
0
|
0.27
|
-3.20
|
0.32
|
-3.65
|
可以计算得到折减系数ψ为0.63。因在最大试验荷载下变形较小,未达到竖向抗压承载力极限状态,如按等效加载P-s曲线在桩顶最大沉降量40mm时的极限承载力推算加载箱位置的荷载为16773/2=8386kN,可以计算得到折减系数ψ为0.68。在本试验场地持力层为圆砾层时,静钻根植桩的桩端极限端阻力可按预制桩桩端极限端阻力的2/3取值。|
桩型
|
规格
|
加载箱距桩
端位置 /m
|
最大加载
/kN
|
对应SX
/mm
|
|
静钻根植桩
|
1#桩800mm
|
7
|
2×7800
|
-7.23
|
|
2#桩800mm
|
7
|
2×7800
|
-6.94
|
|
|
钻孔灌注桩
|
1200mm
|
10
|
2×6600
|
-15.60
|
|
1500mm
|
11
|
2×8300
|
-18.67
|
Analysis of Load Transfer Characteristics of Negative Skin Friction on Foundation Piles under Fill Load
下一篇CCTV-4: XCMG Represents China's Equipment Manufacturing in Brazil

2024-09-29 13335 0

2024-09-20 13336 0

2024-09-20 13180 0

2024-09-19 12457 0

Lize City Air Terminal Underground Main Structure Nearing Completion: Maximum Transfer Walk Under 4 Minutes After Operation

Anti-seepage Curtain for Main Lock Pit of CSCEC Port Shenqiu Double-Line Lock Project Completed on Schedule

All Pile Foundations Completed on Quanzhou Baiqi Channel

Hainan Upgrades Housing and Municipal Infrastructure

First Foundation Concrete Pour Successfully Completed for Zambia Kafue West–Muzuma 330kV Transmission Line EPC Project
Hot News
评论 (0)