【解答】:是坑底还是坑壁,坑底管涌的话应该是降水不到位,深基坑一般坑内+坑外深井降水,你可以安排人测量下水位在什么地方,一般要低于坑底标高1-2米;如果是坑壁管涌的话,得看你们是做得什么围护结构,放坡喷锚的话要及时排出坑壁滞水,同时加强抽水。临时处理可以采用高压注浆封堵管涌口,同时加强基坑围护、和周边房屋、土体的监测,分析真正原因后采取措施补救,等到监测数据稳定后则排出风险。降水不够,立即降水,如果管涌较大,可能引起周边地基下沉,对周边建筑物有较大甚至严重影响。请地勘及设计单位立即到现场确定措施。